The radio receiver is not receiving a signal from the calibration module.
01
Check whether the connectors are properly connected to the radio receiver and whether
they are connected to the correct port on the EXCON. See Checking cables.
| The cables are not connected properly | ➔ | Go to Step 2 |
| The cables are connected properly | ➔ | Go to Step 3 |
02
Make sure the radio receiver cables are connected correctly and wait for the radio receiver to connect.
It may take up to 5 minutes for the radio receiver to start up.
| The radio receiver has established a connection | ➔ | The problem is solved. |
| The radio receiver has not established a connection | ➔ | Go to Step 3 |
03
Connect the radio receiver with another cable (e.g. Spare cable).
| The radio receiver has established a connection | ➔ | The problem is solved. |
| The radio receiver has not established a connection | ➔ | Remove the radio receiver from the system. The radio receiver must be returned to the local supplier for repair. Go to Deploy spare radio receiver. |