Calibrating the positioning system fails

01

Make sure there are no obstacles between the calibration module and the radio receivers and check in Location setup whether
the frequency values ​​(Hz) behind the radio receivers do not fluctuate too much.

The frequency values ​​of the radio receivers fluctuate a lot➔Move the calibration module a few meters and re-measure the field according to the instructions in Training Field Survey. Then go to Step 2
The frequency values ​​of the radio receivers are stable➔Go to Step 3
02

Connect the laser measurement module with the accompanying USB cable to the USB port on
the EXCON and click on the EXCON on Import laser tool. The measured values ​​are read in.

Green check mark behind the button
All measured values ​​have been read in correctly.
➔Go to Step 3
Red cross behind the button
The measured values ​​cannot be read correctly.
➔Go to Importing laser tool does not work.
03

On the EXCON, click Start Calibration again. The system is being calibrated.

Green check mark behind the button
The calibration went well.
➔The problem is solved.
Red cross behind the button
Calibration did not go well.
➔Please contact local supplier.