Poor system positioning

01

On the EXCON, go to Location setup and open the Advanced settings bar on the right side of the screen. Enable the tags by checking the case for
Tags under the Radio Diagnostics tab.

02

Check in the viewport what happens to the tags.

The measurements look something like shown in the picture belowGo to Step 3
The measurements do not look the same as shown in the picture belowPlease contact local supplier
03

Restart the EXCON:

  1. Shut down the EXCON by clicking shut down from the Windows Start menu. Wait for the computer to shut down completely.
  2. Press the red ON/OFF switch on the back of the EXCON to O.
  3. Press the red ON/OFF switch on the back of the EXCON on I again.
  4. Press the ON/OFF button on the front of the EXCON to start up the computer and wait for it to boot up completely.
  5. Enter the password on the computer and press Enter to prevent the system from shutting down again.
  6. Enter the password for the external hard drive and click Unlock to be able to start SUIT.
  7. Double click on the SUIT icon to start SUIT.
04

Import the measurements from the laser survey tool according to the instructions in Read measured data.

The positioning of the system is correctThe problem is solved.
The positioning of the system is correctGo to Step 5
05

Make a log of the problems:

  1. On the EXCON, go to Location setup and open the Advanced settings bar on the right side of the screen. Click on Enable logging at the bottom.
  2. Have each person with an incorrectly positioned Smartvest walk across the length of the field according to the pattern below:
  3. Then let them walk across the width of the field in the same pattern.
  4. In the Advanced settings bar (under Location setup) click again on Disable logging and immediately after clicking copy the entire local folder
    from C:\re-lion\SUIT\SUIT_NLMoD_revxxxx_ddxxxx-xx-xx\working_copy\local to the USB stick